Item(s) Added To Your Bag

UNIKS C-128 Digital TRMS AC|DC Clamp Meter

Click To Zoom

UNIKS C-128 Digital TRMS AC|DC Clamp Meter

UNIKS C-128 Digital TRMS AC|DC Clamp Meter

(Based On 10 Reviews)

The Metravi Uniks Clamp Meters is designed for use in both industrial and civil sectors. It carries out TRMS measurements of voltage up to 1000V AC/DC* and current from 0.1A up to 1000A AC.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments Details

SECURE Payments

₹ 14,850.00

(GST inclusive price) i
  • Base Value: ₹ 12584.7
  • GST: (18) % ₹ 2265.3
  • Total Value ₹ 14850

₹14,850.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • TRMS AC Current: 0-60A/600/1000A
  • Accuracy: ±2.5% reading +8 digits
  • DC Current: 0-60A/600/1000A
  • Accuracy: ±3% reading +10 digits
  • TRMS AC Voltage: 0-6V/60/600/1000V
  • Accuracy: ±0.8% reading +5 digits
  • DC Voltage: 0-6V/60/600/1000V
  • Accuracy: ±0.5% reading +5 digits
  • Resistance: 600Ω/6kΩ/60/600/6MΩ/60MΩ
  • Accuracy: ±1.0% reading +3 digits
  • Capacitance: 60.00nF/6.000/600.0uF/60.00/600.0/6.000mF/60.00mF
  • Accuracy: ±4.0% reading +3 digits
  • K-type Temperature: -20° to 1000°C / -4° to 1832°F
  • Accuracy: ±2.0% reading +2 digits
  • Frequency: 100Hz/1000/10kHz
  • Non-contact Voltage detection
  • InRush Current
  • Voltage measurement with low impedance VLoz
  • Voltage and Current VFD Filter
  • Duty Cycle
  • Diode Test
  • Polarity Test
  • Auto and Manual Range
  • Bandwidth for TRMS measurements of 1KHz
  • Relative measurements
  • Display: 6000 Counts 2 inch Backlit LCD
  • REL function
  • Data Hold
  • Sampling Time: 3 times/second
  • Power supply: 1.5V AAA battery ×3
  • Low battery indication
  • Auto Power-off
  • Built-in LED Flashlight
  • Over Range indication
  • Overload Protection
  • Input protection from over-voltage 1000V AC/DC RMS
  • Certifications: CATIV 600V, CATIII 1000

 

What's in the box?

  •  Digital TRMS AC|DC Clamp Meter

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

General Specification 
Non-contact Voltage detection
InRush Current
Voltage measurement with low impedance VLoz
Voltage and Current VFD Filter
Duty Cycle
Diode Test
Polarity Test
Auto and Manual Range
Bandwidth for TRMS measurements of 1KHz
Relative measurements
6000 Counts 2 inch Backlit LCD Display
REL function
Data Hold
Sampling Time 3 times/second
Power supply: 1.5V AAA battery ×3
Low battery indication
Auto Power-off
Built-in LED Flashlight
Over Range indication
Overload Protection
Input protection from overvoltage 1000V AC/DC RMS
Certified CATIV 600V, CATIII 1000V

 

Technical Specification
AC Current TRMS
Range Resolution Accuracy 
60A 0.01A (2.5% reading +8 digits)
600A 0.1A 
1000A 1A 
- Minimum input value of AC current:0.1A(RMS)
- Maximum input value of AC current:1000A(RMS)
- Frequency range:45Hz~1000Hz

 

DC current (only C128 model)
Range Resolution Accuracy 
60A 0.01A (3.0% reading +10 digits)
600A 0.1A 
1000A 1A 
- Minimum input value of DC current:60mA
- Maximum input value of DC current:1000A

 

AC Voltage TRMS
Range Resolution Accuracy 
6V 0.001V (0.8% reading +5 digits)
60V 0.01V
600V 0.1V 
1000V1V(1.0% reading +5 digits)
- Minimum input value of AC voltage:1mV(RMS)
- Maximum input value of AC voltage:1000V(RMS)
- Frequency range:45Hz~1000Hz

 

DC Voltage 
RangeResolutionAccuracy
6V0.001V1V 
60V0.01V
600V 0.1V 
1000V 1V 
 Minimum input value of DC voltage:1mV
- Maximum input value of DC voltage:1000V

 

Frequency / Duty Cycle Current frequency
Range ResolutionAccuracy 
100Hz 0.01Hz 1.0% reading +5 digits)
1000Hz 0.1Hz 
10kHz 0.001kHz
1%-99% 0.1% 3.0% reading +2 digits)
- Frequency input range:10Hz~10kHz
- Input signal range:≥ 30A AC current(RMS) 

 

Voltage Frequency
Range ResolutionAccuracy
100Hz 0.01Hz 0.1% 
1000Hz 0.1Hz 
10kHz 0.001kHz 
1%-99% 0.1% 3.0% reading + 2 digits)
- Frequency input range:10Hz~10kHz
- Input signal range:≥ 0.8V AC voltage(RMS)

 

Diode
RangeResolutionAccuracy
2.000V 0.001V Displays approximate value of
diode forward voltage drop 
- Overload protection:1000V DC or AC(RMS)

 

Resistance 
Range ResolutionAccuracy 
Ω600Ω0.1±(1.0% reading +3 digits)
6kΩ0.001kΩ
60kΩ0.01kΩ
600kΩ0.1kΩ
6MΩ0.001MΩ
60MΩ0.01MΩ±(1.2% reading +30 digits)
Overload protection:1000V DC or AC(RMS)

 

Capacitance
Range ResolutionAccuracy 
60.00nF 0.01nF±(4.0% reading +3 digits)
600.0nF0.1nF
6.000uF 1nF 
60.00uF 10nF 
600.0uF 100nF 
6.000mF 1uF 
60.00mF 10uF ±(5.0% reading +5 digits)
Overload protection:1000V DC or AC(RMS)

 

Temperature (K-Type)
Range Resolution Accuracy 
-20~1000℃
(-4~1832℉)
1℃/2℉±(2.0% reading +2 digits)
- Overload protection:1000V DC or AC(RMS) 

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0